Since completion of the second major maintenance turnaround on February 28, 1982, the H-Coal Pilot Plant operated for 133.2 days on coal and 54.8 days on oil circulation. Approximately 9600 tons of Wyodak, 12,976 tons of Illinois No. 6 and 3329 tons of Kentucky No. 9 coal (see analyses, Attachment 1, Page 1.0) have been processed in three separate test runs. On November 11, 1982, the final test run was voluntarily terminated following depletion of operational funds and satisfactory completion of operating objectives. The plant was then readied for the third and final shutdown inspection. This report summarizes the observations and results of the final equipment inspection for the period of November 22, 1982, to January 22, 1983. (ERA citation 08:055359)