首页> 美国政府科技报告 >Ventilation Efficiencies of Wall- or Window-Mounted Residential Air-to-Air Heat Exchangers
【24h】

Ventilation Efficiencies of Wall- or Window-Mounted Residential Air-to-Air Heat Exchangers

机译:壁挂式或窗式住宅空气 - 空气热交换器的通风效率

获取原文

摘要

Mechanical ventilation systems with air-to-air heat exchangers can be installed into residences to provide energy-efficient supplementary ventilation for the purpose of controlling indoor concentrations of contaminants, odors, and moisture. Wall- or window-mounted units have become particularly attractive because they are relatively inexpensive and easy to install. However, because they lack an air-distribution system, concern has arisen over their ventilation performance. To address this concern, a series of experiments was conducted on two different models of wall- or window-mounted heat exchangers in two multi-room research facilities. The nominal ventilation efficiencies of these units have been determined by measurement of tracer-gas decay rates at several indoor locations to be in the range of 0.44 to 0.65. No significant correlations between nominal ventilation efficiency and heat exchanger model or operational strategies were observed. Significantly higher local ventilation efficiencies were noted in the rooms where the heat exchangers were operating. Some preliminary tests indicate that internal leakage between the airstreams contributes significantly to the ventilation inefficiency of these systems. (ERA citation 08:049427)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有