首页> 美国政府科技报告 >In-Situ Tuff Water Migration/Heater Experiment: Posttest Thermal Analysis
【24h】

In-Situ Tuff Water Migration/Heater Experiment: Posttest Thermal Analysis

机译:原位凝灰岩水迁移/加热器实验:后测热分析

获取原文

摘要

This report describes posttest laboratory experiments and thermal computations for the In-Situ Tuff Water Migration/Heater Experiment that was conducted in Grouse Canyon Welded Tuff in G-Tunnel, Nevada Test Site. Posttest laboratory experiments were designed to determine the accuracy of the temperatures measured by the rockwall thermocouples during the in-situ test. The posttest laboratory experiments showed that the measured in-situ rockwall temperatures were 10 to 20 exp 0 C higher than the true rockwall temperatures. The posttest computational results, obtained with the thermal conduction code COYOTE, were compared with the experimentally obtained data and with calculated pretest results. Daily heater output power fluctuations (+-4%) caused by input power line variations and the sensitivity of temperature to heater output power required care in selecting the average heater output power values used in the code. The posttest calculated results compare reasonably well with the experimental data. 10 references, 14 figures, 5 tables. (ERA citation 09:005800)