首页> 美国政府科技报告 >Corrosion in Fractionation Towers. Report for the Technical Data Analysis Program
【24h】

Corrosion in Fractionation Towers. Report for the Technical Data Analysis Program

机译:分馏塔的腐蚀。技术数据分析计划的报告

获取原文

摘要

This report reviews the corrosion experience in fractionation towers at both the Process Development Unit P-99 at Gulf Research and Development Company's Harmarville (Pa.) facility and the Ft. Lewis Pilot Plant at Tacoma, Washington. At both these units, evidence indicates chloride containing feed to the towers as the source of corrosion. The results of desalter tests conducted by Petreco Division of Petrolite Corporation on high chloride containing Ft. Lewis atmospheric tower feed samples are also reported. In addition, features to reduce corrosion that were to be incorporated into the planned SRC-II Demonstration Plant are described. The report from Fort Lewis is attached as an appendix and has been entered individually into EDB and ERA. (ERA citation 09:047272)