首页> 美国政府科技报告 >Volatiles Mass Transport within Particles of Softened Coal. Technical Progress Report, October 27, 1983-January 26, 1984
【24h】

Volatiles Mass Transport within Particles of Softened Coal. Technical Progress Report, October 27, 1983-January 26, 1984

机译:软化煤颗粒内挥发物的质量传递。技术进步报告,1983年10月27日 - 1984年1月26日

获取原文

摘要

In order to obtain data on the molecular weight distribution of coal tar and pyridine extract of char, Gel Permeation Chromatography has been employed to separate the coal tar according to molecular size. The chromatographic system used was a Waters Associates ALC/GPC 201 Gel Permeation Chromatography system with 500 A and 100 A mu -styragel columns. Although the approximate molecular weight range for the columns has been determined by the manufacturer and there are standards of known molecular weight available, it is still necessary to calibrate the columns with coal tars since the calibration curve will be unique for the particular tars that are to be studied. The peak position method and the linear calibration method are both described and the results are compared. 1 reference, 3 tables, 3 figures. (ERA citation 09:025242)