首页> 美国政府科技报告 >Industrial Application of Computer Assisted Tomography. Detection, Location and Sizing of Shrink Cavities in Valve Castings
【24h】

Industrial Application of Computer Assisted Tomography. Detection, Location and Sizing of Shrink Cavities in Valve Castings

机译:计算机辅助层析成像的工业应用。阀门铸件收缩腔的检测,定位和尺寸

获取原文

摘要

Computer assisted tomography (CAT) scanning is a nondestructive testing technique used to obtain quantitatively accurate mappings of the distribution of linear attenuation coefficients inside an object. To demonstrate the potential of the technique for accurately locating defects in three dimensions a sectioned 5 cm gate valve, with a shrink cavity made visible by the sectioning, was tomographically imaged using a Co-60 source. The tomographic images revealed a larger cavity below the sectioned surface. The position of this cavity was located with an in-plane and axial precision of approximately +-1 mm. The volume of the cavity was estimated to be approximately 40 mm exp 3 . (Atomindex citation 16:054554)