首页> 美国政府科技报告 >BODYFIT-2PE-HEM: LWR Core Thermal-Hydraulic Code Using Boundary-Fitted Coordinates and Two-Phase Homogeneous Equilibrium Model. Volume 3: Validation and Applications
【24h】

BODYFIT-2PE-HEM: LWR Core Thermal-Hydraulic Code Using Boundary-Fitted Coordinates and Two-Phase Homogeneous Equilibrium Model. Volume 3: Validation and Applications

机译:BODYFIT-2pE-HEm:使用边界拟合坐标和两相均匀平衡模型的LWR核心热工水力学代码。第3卷:验证和应用

获取原文

摘要

The BODYFIT-2PE-HEM code was used to simulate several Pressurized Water Reactor (PWR) and Boiling Water Reactor (BWR) types of experiments to validate its applicability and accuracy. Five simulations are reported in this volume. The first comparison was between the closed form analytical solution and the BODYFIT calculation of 3-D flows in an inifinite square array of circular tubes. Both the velocity profiles along symmetry lines and Nusselt numbers as a function of the entrance distance were given in the report. The second simulation was on the Columbia University 4 x 4 rod bundle experiment with a power skew of 2 to 1. The calculated mass flow rates and qualities for both hot and cold subchannels at the exit of the rod bundle were compared with the experimental isokinetic measurements. The third simulation was on the Babcock and Wilcox 4 x 6 rod bundle experiments with a power skew of 1.5 to 1. Again, the calculated mass flow rates and qualities for both hot and cold subchannels at the exit of the rod bundle were compared with the experimental isokinetic measurements. The fourth simulation was on the Westinghouse 4 x 5 rod bundle critical heat flux experiments and transient pressure drop tests. In this simulation, the critical heat fluxes calculated by the code with several CHF correlations were compared with the experimental measurements. Furthermore, the pressure drops, as a function of time, were compared with the experimental values for the flow rundown transients. The fifth simulation was on the GE 3 x 3 CHF experiments. Many operating conditions with different inlet temperatures, inlet velocities, and system pressures were used in the experiments. Code calculations were based on the Biasi correlation and the Columbia University correlation. Comparisons between calcuations and measurements show good agreements, demonstrating the validity and accuracy of the BODYFIT-2PE-HEM code. 14 refs., 36 figs., 11 tabs. (ERA citation 10:048592)

著录项

相似文献

  • 外文文献
  • 中文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号