An experiment was conducted to determine if the oxygen supply in a CuO catalyst considered for use in the TMIST-2 irradiation test would be sufficient to convert all the hydrogen isotopes coming from the irradiation test to water. A mixture of 2% H2 in Ar was supplied to a modified MRB 500 stack m onitor from Mound Techology Solutions, Miamisburg, OH. It was found that the catalyst could convert 3.75E-03 moles of H2 before losing its effectiveness. Conversion was found to begin at a catalyst temperature of about 220 deg C and to be fully effective at about 300 deg C.