首页> 美国政府科技报告 >Methods Validation Study of High Performance Liquid Chromatographic Technique for Determining the MPDA and MDA Content of Air Samples. Final Report
【24h】

Methods Validation Study of High Performance Liquid Chromatographic Technique for Determining the MPDA and MDA Content of Air Samples. Final Report

机译:方法高效液相色谱法测定空气中mpDa和mDa含量的方法验证。总结报告

获取原文

摘要

Development and validation studies were completed for a method for monitoring worker exposure to the compounds m-phenylenediamine (MPDA) and 4,4'-methylenedianiline (MDA). These amine compounds are used with certain epoxy resins in gas-centrifuge rotor manufacturing operations. Several techniques for preparing test atmospheres of these amines and the epoxy resins were studied. 8 refs., 6 figs., 11 tabs. (ERA citation 11:023809)