首页> 美国政府科技报告 >Ultrasonic Examination of Defects Close to the Outer Surface
【24h】

Ultrasonic Examination of Defects Close to the Outer Surface

机译:超声检查靠近外表面的缺陷

获取原文

摘要

During the examination of a pressurized water reactor vessel with an in Service Inspection Machine (MIS), various welds are scanned with immersion ultrasonic focused transducers from the inside of the vessel. Defects close to the outer surface are sometimes detected, and sizing with the successive 6 dB drop method leads to oversize some indications; this is caused by various reflections on the outer wall; the corner echo is of particular importance here. CEA and EDF have started an experimental program in order to study the response of volumetric and planar defects located near the outer surface. We present here the first results obtained with artificial defects. 2 references. (ERA citation 13:000691)