首页> 美国政府科技报告 >10 MW/sub E/ Solar Thermal Central Receiver Pilot Plant Mirror Module Corrosion Torque Tube Damage and Vent Tube Assessment Survey, July 1985 and July 1986
【24h】

10 MW/sub E/ Solar Thermal Central Receiver Pilot Plant Mirror Module Corrosion Torque Tube Damage and Vent Tube Assessment Survey, July 1985 and July 1986

机译:10 mW / sub E /太阳能热中央接收器试验工厂镜子模块腐蚀扭矩管损坏和通风管评估调查,1985年7月和1986年7月

获取原文

摘要

This report documents the results of the July 1985 and July 1986 surveys of mirror module corrosion and torque tube damage at the 10 MW/sub e/ Solar Thermal Central Receiver Pilot Plant. It also assesses the effect of vent tubes on the corrosion growth rate. Results show that 0.052% and 0.061% of the total reflective area of the heliostat field was corroded in 1985 and 1986, respectively. However, the corrosion growth rate is much less than in previous years, primarily because of the effect of mirror module vent tubes. In the July 1984 survey, 35 torque tubes were damaged due to impact with the gear box. The 1985 survey showed that 14 of those same torque tubes were re-damaged. In addition, 9 newly dented ones were found. In the July 1986 survey, 39 torque tubes were dented, of which 4 were redented from 1985. The denting is caused when the gear-drive travels past the limit switch due to a shorted diode in parallel with the limit switch. (ERA citation 13:000560)

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号