The storage ring vacuum chamber of the proposed 7-GeV synchrotron light source at Argonne National Laboratory is planned to have a semi-elliptical beam chamber, with a longitudinal slot coupled to an antechamber containing NEG pumping strips. Concern over the RF impedance of this complex chamber has stimulated the need to understand the limitations it will have on the beam intensity, the RF acceleration system and on the beam lifetime. Calculations using numerical EM field programs have estimated the waveguide modes of this chamber and the impedance and loss parameter for the expected 1 to 2 cm beam bunch length. The loss parameter is shown to differ little from an elliptical beam chamber without the slot and antechamber. An experimental program has begun to verify the estimates of the impedance for these complex vacuum chamber components using laboratory methods. Preliminary results are presented for the measured loss parameter for a short length of beam vacuum chamber and for other components. These results are compared with their calculated values. (ERA citation 12:043844)