首页> 美国政府科技报告 >Role of Natural Circulation in the FFTF (Fast Flux Test Facility) Passive Safety Tests
【24h】

Role of Natural Circulation in the FFTF (Fast Flux Test Facility) Passive Safety Tests

机译:自然循环在FFTF(快速通量测试设施)被动安全测试中的作用

获取原文

摘要

A series of tests were completed at the Fast Flux Test Facility to demonstrate the passive safety characteristics of liquid metal reactors with natural circulation flow. The first test consisted of transition from forced to natural circulation flow at an initial decay power of 0.3%. The second test represented an unprotected loss-of-flow transient to natural circulation from 50% power with the control rods prevented from scramming into the core. The third test was a steady-state, natural circulation condition with core fission powers up ato about 2.3%. Core sodium data and results of single and multi-channel computer models confirmed the reliability and effectiveness of natural circulation flow for liquid metal reactor safety. (ERA citation 13:003488)