首页> 美国政府科技报告 >Microstructural Evolution and Response to Double-Loop Reactivation Testing of Heat-Treated pH 13-8 Mo Martensitic Stainless Steel
【24h】

Microstructural Evolution and Response to Double-Loop Reactivation Testing of Heat-Treated pH 13-8 Mo Martensitic Stainless Steel

机译:热处理pH 13-8 mo马氏体不锈钢的微观结构演变及对双环再活化试验的响应

获取原文

摘要

The double loop electrochemical potentiokinetic reactivation (DL-EPR) test was used to investigate the intergranular and interlath corrosion susceptibility of pH 13-8 Mo as a function of heat treatment. Degree of sensitization was measured to the ratio of the peak current on a reverse (reactivation) scan to that on the forward anodic scan. Corrosion morphology was characterized by SEM, and microstructure by AEM. PH 13-8 Mo in the as-received condition was not sensitized. Precipitation-strengthening to the H925 temper caused susceptibility to intergranular corrosion, and averaging at H1150 caused susceptibility to interlath corrosion. Corrosion susceptibility was most likely caused by a classic Cr-depletion mechanism. 4 refs., 3 figs. (ERA citation 12:045737)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号