首页> 美国政府科技报告 >Weld Region Corrosion During Chemical Cleaning of PWR Steam Generators Volume 2:Tests and Analyses
【24h】

Weld Region Corrosion During Chemical Cleaning of PWR Steam Generators Volume 2:Tests and Analyses

机译:压水堆蒸汽发生器化学清洗过程中的焊接区域腐蚀第2卷:试验和分析

获取原文

摘要

The investigations included development and use of a corrosion assessment test facility which measured corrosion currents in a realistic model of the steam generator geometry in the vicinity of a specific weld during a simulated chemical dissolution of sludge consisting of essentially pure magnetite. A corrosion monitoring technique was developed and qualified. In this technique free corrosion rates measured by linear polarization techniques are added to corrosion rates calculated from galvanic current measured using a zero resistance ammeter to give an estimate of total corrosion rate for a galvanically corroding material.nAn analytic modeling technique was developed and proved useful in determining the size requirements for the weld region mockup used in the corrosion assessment test facility. The technique predicted galvanic corrosion rates consistent with that observed in a corrosion assessment test when polarization data used as model input were obtained on-line during the test.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号