首页> 美国政府科技报告 >Evaluation of PNS (Parabolized Navier-Stokes)-Computed Heating and Hypersonic Shock Tunnel Data on Sharp and Inclined Blunt Cones
【24h】

Evaluation of PNS (Parabolized Navier-Stokes)-Computed Heating and Hypersonic Shock Tunnel Data on Sharp and Inclined Blunt Cones

机译:评估pNs(抛物化Navier-stokes) - 尖锐和倾斜钝锥上的计算加热和高超声速冲击隧道数据

获取原文

摘要

As part of the ongoing development and verification of the Parabolized Navier-Stokes (PNS) technique, computed heat transfer rates have been compared with recently acquired experimental data. The flow fields were computer for laminar and turbulent flow over sharp, blunt tripped sphere-cones at 0/degree/ to 20/degree/ angle of attack in a hypersonic shock tunnel flow at Mach numbers of 11, 13, and 16. Grid refinement studies were performed and minimum smoothing parameters were sought. The average percent difference between the measured mean heat transfer rate and the PNS-computed value was 12% for the sharp and blunt cones at 0/degree/ angle of attack. For the blunt cones at angle of attack, the average percent difference was 11% on the windward ray and 36% on the leeward ray. PNS-predicted flow physics such as boundary layer thickness, shock standoff distance, and crossflow separation were examined. 15 refs., 12 figs. (ERA citation 14:006275)