首页> 美国政府科技报告 >Study of wire chambers with highly segmented cathode pad readout for high multiplicity, charged particle detection.
【24h】

Study of wire chambers with highly segmented cathode pad readout for high multiplicity, charged particle detection.

机译:研究具有高度分段阴极垫读数的线室,用于高多重性,带电粒子检测。

获取原文

摘要

Investigations for interpolating cathode ''pad'' readout have been carried out for high multiplicity, two dimensional position sensitive detection of minimum ionizing particles and heavy ions. A detector configuration representing only 0.6% of a radiation length and covering an area of 26 cm by 16 cm, with over 1000 readout channels, has been developed. In a prototype chamber using this technique, a resolution of less than 100 (mu)m rms, for 5.4 keV x-ray, and differential nonlinearity of (plus minus)6% have been achieved. The technique has also been demonstrated for detectors of much larger area. 12 refs., 11 figs.