首页> 美国政府科技报告 >Posttest Analysis of the 1:6-Scale Reinforced Concrete Containment.
【24h】

Posttest Analysis of the 1:6-Scale Reinforced Concrete Containment.

机译:1:6级钢筋混凝土遏制后测分析。

获取原文

摘要

A prediction of the response of the Sandia National Laboratories 1:6- scale reinforced concrete containment model test was made by Argonne National Laboratory. ANL along with nine other organizations performed a detailed nonlinear response analysis of the 1:6-scale model containment subjected to overpressurization in the fall of 1986. The two-dimensional code TEMP-STRESS and the three-dimensional NEPTUNE code were utilized (1) to predict the global response of the structure, (2) to identify global failure sites and the corresponding failure pressures and (3) to identify some local failure sites and pressure levels. A series of axisymmetric models was studied with the two-dimensional computer program TEMP-STRESS. The comparison of these pretest computations with test data from the containment model has provided a test for the capability of the respective finite element codes to predict global failure modes, and hence serves as a validation of these codes. Only the two-dimensional analyses will be discussed in this paper. 3 refs., 10 figs.