摘要

Helium glow discharge conditioning is used before every discharge in the D3-D Tokamak to desorb hydrogen and low Z impurities from the graphite and Inconel plasma facing surfaces. However high gas pressure is required to initiate each glow discharge session and this requires frequent cycling of valves to protect pressure sensitive devices. To alleviate this mechanical fatigue an electron gun assisted glow system (EAG) is being installed on the D3-D vessel to lower the initiation pressure. Through the injection of electrons the initiation pressure of the helium glow discharge has been lowered by a factor of 70, bringing the initiation pressure within a factor of 2 of the minimum sustaining pressure of the glow discharge. This might also make possible pulsed glow conditioning which would allow a lower average pressure during glow conditioning reducing the heat load on proposed cryogenic pumping panels. Experimental results of the electron assist on He glow initiation and a scaling model for the electron gun assisted glow will be presented. The electron gun can also be used as a diagnostic. Without a glow discharge, the electron gun has been pulsed into the wall and desorbed gas measured by a Residual Gas Analyzer. We are attempting to correlate the desorbed gas with recycling or vessel cleanliness. (ERA citation 17:008343)