首页> 美国政府科技报告 >Hanford Double Shell Tank Thermal and Seismic Project Increased Liquid Level Analysis for 241-AP Tank Farms
【24h】

Hanford Double Shell Tank Thermal and Seismic Project Increased Liquid Level Analysis for 241-AP Tank Farms

机译:Hanford双壳储罐热和地震项目增加了241-ap油罐区的液位分析

获取原文

摘要

The essential difference between Revision 1 and the original issue of this report is the analysis of the anchor bolts that tie the steel dome of the primary tank to the concrete tank dome. The reevaluation of the AP anchor bolts showed that (for a given temperature increase) the anchor shear load distribution did not change significantly from the initially higher stiffness to the new secant shear stiffness. Therefore, the forces and displacements of the other tank components such as the primary tanks stresses, secondary liner strains, and concrete tank forces and moments also did not change significantly. Consequently, the revised work in Revision 1 focused on the changes in the anchor bolt responses and a full reevaluation of all tank components was judged to be unnecessary.