首页> 美国政府科技报告 >Fragment hazard zone analyses for explosive test facilities
【24h】

Fragment hazard zone analyses for explosive test facilities

机译:爆炸试验设施的碎片危险区域分析

获取原文

摘要

The analytical procedures for establishing the fragment hazard zone for explosive test facilities are presented. Environment, safety and health regulations require that a hazard zone analysis be conducted for every explosive test facility. Analyses are presented for explosively driven missile fragment trajectories resultant from cased explosive configurations. Fragment trajectory parameter data are presented in graphical form for three different fragment materials (aluminum, steel and tantalum), initial velocities between 0.6mm/(mu)s (2000 ft/sec) to 4.3mm/(mu)s (14,000 ft/sec), and for various geometries. This trajectory information is used, as an example, to determine the safe distance or hazard zone for the Area 2 explosive test facility at Sandia National Laboratories.

著录项

  • 作者

    Vigil, M G;

  • 作者单位
  • 年度 1992
  • 页码 1-59
  • 总页数 59
  • 原文格式 PDF
  • 正文语种 eng
  • 中图分类 工业技术;
  • 关键词

    EDB/450100;

    机译:EDB / 450100;