首页> 美国政府科技报告 >Residential Forced Air System Cabinet Leakage and Blower Performance
【24h】

Residential Forced Air System Cabinet Leakage and Blower Performance

机译:住宅强制通风系统机柜泄漏和鼓风机性能

获取原文

摘要

This project evaluated the air leakage and electric power consumption of Residential HVAC components, with a particular focus on air leakage of furnace cabinets. Laboratory testing of HVAC components indicated that air leakage can be significant and highly variable from unit to unit - indicating the need for a standard test method and specifying maximum allowable air leakage in California State energy codes. To further this effort, this project provided technical assistance for the development of a national standard for Residential HVAC equipment air leakage. This standard is being developed by ASHRAE and is called 'ASHRAE Standard 193P - Method of test for Determining the Air Leakage Rate of HVAC Equipment'. The final part of this project evaluated techniques for measurement of furnace blower power consumption. A draft test procedure for power consumption was developed in collaboration with the Canadian General Standards Board: CSA 823 'Performance Standard for air handlers in residential space conditioning systems'.