Storage ring based inverse Compton scattering angiography source.

机译:基于存储环的逆康普顿散射血管造影源。

获取原文

摘要

Producing the 33.17 keV photons required for coronary angiography with synchrotron radiation requires a combination of a high energy storage ring with an extremely high field wiggler. Such a source may be too big and expensive to be installed in even the largest medical center. Something other than synchrotron radiation may be needed for a practical source. Inverse Compton scattering has been used in the LEGS experiment at NSLS and elsewhere to produce high energy photons. In this process, a head on collision between a low energy photon and a high energy electron transfers energy to the photon which is then emitted in approximately the direction of the incoming electron. For a given electron energy, more higher energy photons can be produced by this method than by synchrotron radiation. This suggests that inverse Compton scattering can possibly be used for a low cost angiography source. The prospects for such a source will be examined in this paper. Unfortunately, the results will show that although it is easy to obtain the required photon energy, an extremely complicated source will be needed to produce the required number of photons.