首页> 美国政府科技报告 >Resistance of a Commercial Magnetorheological Fluid to Penetration.
【24h】

Resistance of a Commercial Magnetorheological Fluid to Penetration.

机译:商业磁流变液对渗透性的抵抗力。

获取原文

摘要

The stress required to penetrate a commercial magnetorheological (MR) fluid exposed to an applied magnetic field, B, in the range of 0 - 0.25 Tesla was determined for: (a) a constant, continuous field and (b) on-off field. With constant field application, it was found that vs. the penetration depth, x, of the cylindrical indenter into the MR fluid at a constant rate of 0.12- 0.18 mm/s was parabolic in form, namely = (sub o)x(expn n) where (sub 0) = AH, A = 1.7 kPa/(kA/m) and n = 0.3-0.5. The magnitude of o is approximately six times that of the shear yield stress, (sub y), of the MR fluid. A model is proposed to explain the resistance to penetration into the MR fluid with the constant field. The results obtained in the on-off field tests and the in-out tests are in keeping with the model.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信