首页> 美国政府科技报告 >Treatability Study in Support of Remediation by Natural Attenuation for Groundwater at Site FTA-2
【24h】

Treatability Study in Support of Remediation by Natural Attenuation for Groundwater at Site FTA-2

机译:现场FTa-2地下水自然衰减补偿的可处理性研究

获取原文

摘要

This report presents the results of a remediation by natural attenuation treatability study (RNA TS) performed by Parsons Engineering Science, Inc. (Parsons ES) at Fire Training Area 2 (FTA-2), Tinker Air Force Base (AFB), Oklahoma. The RNA TS was performed to evaluate the use of natural attenuation with long-term monitoring (LTM) as a remedial option for dissolved chlorinated aliphatic hydrocarbon (CAM) contamination in the upper saturated zone (USZ). The presence of groundwater contamination and soil contamination at the site was documented during remedial investigations performed by International Technology Corporation (IT) (1994) and Tetra Tech (TT) (1996). This TS focused on the impact of dissolved CAHs, primarily trichloroethane (TCE) , on the USZ groundwater system at, and downgradient from, the site. Site history and the results of soil and groundwater investigations conducted previously also are summarized in this report.