首页> 美国政府科技报告 >Acoustically Forced Heat Transfer from a Tube Bank
【24h】

Acoustically Forced Heat Transfer from a Tube Bank

机译:来自管束的声学强制传热

获取原文

摘要

Experimental work was carried out on the steady state heat transfer behavior from a tube bank in a zero mean oscillatory flow. The oscillatory flow across the tube bank was created by an acoustic field inside an isolated resonant chamber. The tube bank was represented by smooth walled cylinders placed parallel to each other, with their plane normal to the direction of fluid oscillation, similar to the arrangement found in many heat exchangers. The spacing between the cylinders was varied to examine the effects of boundary layer interference on the heat transfer behavior. Heat transfer correlations were developed in the form of Nusselt number as a function of the streaming Reynolds number for each tube spacing. This experimental study is relevant to the design of heat exchangers for thermoacoustic engines.