首页> 美国政府科技报告 >Chromate Content Bias as a Function of Particle Size in Aircraft Primer Paint Overspray
【24h】

Chromate Content Bias as a Function of Particle Size in Aircraft Primer Paint Overspray

机译:铬酸盐含量偏差作为粒度的函数在飞机底漆涂料过喷

获取原文

摘要

Spray painting operations using chromate-containing primer paints produce particles which may expose workers to strontium chromate. Chromate contains hexavalent chromium (Cr(VI)) which is a confirmed human carcinogen. It is suspected that the smaller particles contain disproportionately less Cr(VI) than larger particles. In order to determine if a bias in chromate content exists, paint particles were collected and separated based on particle size and the Cr(VI) concentration was determined. Aviation primer paint from the DeSoto and Deft companies was sprayed in a booth and seven-stage cascade impactors were used to separate particles.

著录项

相似文献