首页> 美国政府科技报告 >Shock Tube Measurements Of Iso-Octane Ignition Times And OH concentration Time Histories
【24h】

Shock Tube Measurements Of Iso-Octane Ignition Times And OH concentration Time Histories

机译:冲击管测量异辛烷点火时间和OH浓度时间历史

获取原文

摘要

Ignition times and OH radical concentration time histories were measured behind reflected shock waves in iso-octane/O2/Ar mixtures. Initial reflected shock conditions were in the ranges 1177 to 2009 K and 1.18 to 8.17 atm, with fuel concentrations of 100 ppm to 1% and equivalence ratios from 0.25 to 2. Ignition times were measured using endwall emission of CH and sidewall pressure. OH concentrations were measured using narrow-linewidth ring-dye laser absorption of the R1(5) line of the OH A-X (0,0) band at 306.5 nm. The ignition time data and OH concentration time history measurements were compared to model predictions of four current iso-octane oxidation mechanisms, and the implications of these comparisons are discussed. To our knowledge, these data provide the first extensive measurements of low fuel-concentration ignition times and OH concentration time histories for iso-octane auto-ignition, and hence provide a critical contribution to the database needed for validation of a detailed mechanism for this primary reference fuel.