首页> 美国政府科技报告 >Lab Test of a Prototype HMMWV Air Filter Element Constructed With Microstructured Oriented Fiber (MOF) Filter Media
【24h】

Lab Test of a Prototype HMMWV Air Filter Element Constructed With Microstructured Oriented Fiber (MOF) Filter Media

机译:用微结构定向纤维(mOF)过滤介质构建的原型HmmWV空气过滤器元件的实验室测试

获取原文

摘要

Two prototype Microstructured Oriented Fiber (MOF) air filter elements were designed and built to fit a HMMWV (M998 Utility Truck) multi-stage housing by MicroEnergy Technologies Inc. under contract DAAE07-03-C-L066. During April and May of 2003, the MOF filters underwent dust capacity and efficiency performance testing at the U.S.Army Tank Automotive Research, Development and Engineering Center (TARDEC). The MOF filter did not meet the efficiency or dust capacity performance requirements. The MOF filter attained an efficiency of 66. 78%, which is far lower than the required 99.5%. The MOF filter achieved a dust capacity of 40 minutes, which is considerably less than the required 20 hours. During the efficiency and dust capacity testing, the pressure drop across the master (absolute) filter increased rapidly which indicated the MOF filter was allowing a significant amount of dust to pass through resulting in low performance. The MOF filter is not recommended for the M988 since the dust capacity and initial efficency did net meet the performance requirements.