Evaluation of Differences in Response of DOD Portable Instruments and Solid-State Detectors used by MEXT for Measurement of External Radiations with Attention to the Cosmic Radiation Component

机译:评估mEOD用于测量外部辐射并注意宇宙辐射成分的DOD便携式仪器和固态探测器的响应差异

获取原文

摘要

This report discusses cosmic radiation and summarizes its contributions to radiation dose from external sources and the implications on measurement of external dose-rate using either pressurized ion chambers (PICs) or thallium-activated sodium iodide NaI(Tl). The report finds that some NaI(Tl) systems under respond to cosmic radiation above 3 MeV deposited energy. These differences are offered as one of several contributors to the lower values of external dose rates measured by Japan s Ministry of Education, Culture, Sports, Science, and Technology (MEXT) using NaI(Tl) compared to DOD/DOE measurements using PICs. The report concludes that such limitations must be accounted for in performing assessments of dose from external sources.