Models based on empirical fluid flow and heat transfer data combined with basic principle analysis provide data for estimating the cost of implementing a closed-loop radiant cooling system for ships in dry docks. Depending of the material used, pipe lengths from 300m to 3000m with diameters ranging from 10in to 24in all cooled a design load of 8 F degrees =4.bar(44) K above ambient temperature when that temperature was assumed to be 300 K. From the cost analysis performed, $12 million would be the maximum initial investment for the system that moves 26 million gallons per day (approximately 18000gpm). This leaves $30 million to pay for the other aspects of implementing this system.