首页> 美国政府科技报告 >Calibrated Mid-wave Infrared (IR) (MidIR) and Long-wave IR (LWIR) Stokes and Degree-of-Liner Polarization (DOLP); Final rept
【24h】

Calibrated Mid-wave Infrared (IR) (MidIR) and Long-wave IR (LWIR) Stokes and Degree-of-Liner Polarization (DOLP); Final rept

机译:校准的中波红外(IR)(midIR)和长波IR(LWIR)斯托克斯和线性偏振度(DOLp);最终的评论

获取原文

摘要

We present radiometric and polarimetric calibrated imagery recorded in both the mid-wave infrared (IR) (MidIR) and long-wave IR (LWIR) as a function of diurnal variation over several multiday periods. We compare differences in polarimetric and conventional thermal imagery for both IR atmospheric transmission windows, i.e., the 3-5 mu and 8-12 mu regions. Meteorological parameters measured during the study include temperature, relative humidity, wind speed/direction, precipitation, and ambient atmospheric IR loading. The two camera systems used in the study differed significantly in design. The LWIR polarimetric sensor utilizes a spinning achromatic retarder and is best suited for static scenes, while the MidIR system is based on a division-of-aperture design and is capable of recording polarimetric imagery of targets that are rapidly moving. Examples of both So (conventional thermal) and degree-of-linear polarization (DOLP) imagery are presented and compared.

著录项

相似文献

  • 外文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号