首页> 美国政府科技报告 >Advanced GPS-Based Time Link Calibration with PTB's New GPS Calibration Setup
【24h】

Advanced GPS-Based Time Link Calibration with PTB's New GPS Calibration Setup

机译:基于Gps的高级时间链接校准与pTB的新Gps校准设置

获取原文

摘要

The PTB has assembled an easy-to-use GPS calibration set-up intended for relative time link calibrations, consisting of a GTR50 time and frequency GPS receiver and a SR620 time interval counter integrated in a small rack together with a monitor and a keyboard. Usually locally available time interval counters are used to measure the offset delta t0 between the 1 PPS signal representing the local time scale and the signal that is connected to the traveling receiver in each visited laboratory. In each time interval counter a distinct error for time interval measurement shows up. If only one single counter is used at all participating laboratories this error cancels out, assuming that the properties of this counter do not change during the travel, as it is assumed for the properties of the traveling receiver as well. The calibration set-up was shipped to USNO in mid June 2010 and was used to calibrate the time transfer links between USNO and PTB, in total 16. This large number reflects the multitude of fixed receivers involved and the different kinds of data processing. For all cases the calibration uncertainty is at the level of 2 ns and below. The results have been used to validate an ad-hoc calibration adjustment made earlier by the BIPM to the Ku-band TWSTFT link. A deviation of 3.7 ns compared to the 2008 result was found.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号