Detonation induction distanced were determined in a 9-mm inside diameter detonation tube at on initial pressure of T atm of ambient initial temperature for hydrogen-oxygen mixtures flowing at initial velocities ranging from 1-100 maters / second and for hydrogen-oxygen mixtures flowing at velocities ranging from 0-30 maters. Some experiments with hydrogen-oxygen mixtures were conducted at 9 atm initial pressures.