首页> 美国政府科技报告 >Acoustic Flowmeter Prototype Evaluation Tests.
【24h】

Acoustic Flowmeter Prototype Evaluation Tests.

机译:声学流量计原型评估测试。

获取原文

摘要

Prototype tests of an acoustic flowmeter system were made in a 24-ft-diam power penstock at Oahe Dam to evaluate the system prior to permanent installation in the outlet works at Summersville Dam. Comparative discharge measurements included acoustic,penstock pressure-momentum (Gibson),turbine model test ratings,scroll-case pressure differential (Winter-Kennedy flowmeter),and surge tank volume changes. The acoustic flowmeter measurements were very consistent and many of the comparisons were within 1%. The location of the measuring section for a single-path acoustic flowmeter must be selected to give a known or measurable relation between the flow pattern of the whole section and that along the acoustic path. (Author)