首页> 美国政府科技报告 >Spillway for Oakley Dam Sangamon River, Illinois. Appendix A: Type 2 (Revised) Spillway; Hydraulic Model Investigation
【24h】

Spillway for Oakley Dam Sangamon River, Illinois. Appendix A: Type 2 (Revised) Spillway; Hydraulic Model Investigation

机译:奥克利水坝sangamon河,伊利诺伊的溢洪道。附录a:2型(修订)溢洪道;水力模型研究

获取原文

摘要

A description of the proposed Oakley Dam is contained in Part 1 of the main report, which reported results of tests made on the spillway of original design and to which this is an a appendix. The tests reported herein were considered desirable to verify the adequacy of the spillway after after changes were made in the original design. The general purpose of the model tests was to determine what effect the 7-ft reduction in spillway crest (from el 628 to 621) would have on discharge characteristics, stilling basin performance, and riprap protection. To accomplish the purpose, the revised spillway was constructed to a scale of 1:60 and installed in the existing general model. Details of the model are shown.