Reaction-Time Procedure for Measurment of Hearing. II. Threshold Functions.

机译:用于测量听力的反应时间程序。 II。阈值函数。

获取原文

摘要

The reaction-time (RT) procedure applied to the measured of suprathreshold functions in the proceding paper may also be used to measure threshold. This paper examines threshold contours measured by the RT procedure in human and monkey subjects with normal and impaired hearing. In the human subjects, thresholds obtained using the RT procedure closely parallel those obtained in the clinic but were an average of 2.7 dB lower; RT thresholds were an average of 5dB above thresholds obtained in a force-choice procedure. Thresholds obtained from monkey subjects paralleled the normal human contours within the human frequency range of hearing, but were slightly higher at frequencies below 4kHz and lower at frequencies above 4kHz. The monkeys' hearing extended approximately 1 1/4 octaves above the humans.' Threshold measured using the RT procedure in human and monkey subjected agreed well with thresholds previously reported in the literature. The effects of sound presentation and calibration procedures on the shape and position of the threshold contours are examined in an appendix. (Author)