首页> 美国政府科技报告 >Static, Substained,and Cyclic Load Tests of Steel Pile Connectors. New Orleans District.
【24h】

Static, Substained,and Cyclic Load Tests of Steel Pile Connectors. New Orleans District.

机译:钢管连接器的静态,带状和循环载荷试验。新奥尔良区。

获取原文

摘要

Fourteen pile cap specimens,each containing two,three,or four connectors nailed to a section of saturated,class 'B'timber piling and encased in a concrete pile cap,were subjected to three types of tests conducted under submerged conditions to evaluate the effectiveness of the connectors. The specimens were tested under: (a) static tensile loads to failure to determine the ultimate load that two connectors could withstand, (b) sustained tensile loads at various percentages of the corresponding ultimate loads to determine the effects of percentage of load and duration of load on the slip characteristics of the pile connectors, (c) cyclic loading from tension to compression to determine what effect repetitive loads would have on the amount of slip between the pile and the cap. (Modified author abstract)