首页> 美国政府科技报告 >Effects of Downstream Distance on Turbulence Decay for the Compressor Research Facility Low Conditioning System
【24h】

Effects of Downstream Distance on Turbulence Decay for the Compressor Research Facility Low Conditioning System

机译:下游距离对压缩机研究设施低调节系统湍流衰减的影响

获取原文

摘要

The turbulence decay of the 304.8 cm. (120 in.) diameter flow conditioning system for the Air Force Aero Propulsion Laboratory's Compressor Research Facility was investigated in a 25.4 cm. (10 in.) diameter channel to predict turbulence levels that can be expected at the entrance to compressors being tested in the facility. Results of this experimentation show that the flow conditioning system will meet the design goal of reducing the expected imcoming turbulence level of 30-40% to less than 1% at the entrance to a test compressor. Further, the turbulence decay associated with the full-flow conditioning system and its individual components possesses initial period of decay characteristics throughout the 600 cm. decay length investigated. It is concluded that these decay characteristics are due to the large scale of turbulence incoming and existing the flow conditioning system of the Compressor Research Facility. (Author)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号