The United States Army Aviation Engineering Flight Activity conducted an evaluation of two vibration measuring devices, the Chadwick-Helmuth VIBREX and the Scientific-Atlanta Vibration Signature Recorder, as flight test instrumentation. Durint the course of those evaluations, it was determined that the Dow Corning E2460-40-1 (redesignated E2978-46) ice phobic coating applied to the rotor blades of a UH-1H helicopter, did not induce undesirable vibrations. It was also concluded that the VIBREX may be used as test instrumentation if the frequencies of interest are already known, and the Scientific-Atlanta device provides good 'quick look' spectral vibration data. (Author)