首页> 美国政府科技报告 >Performance of the Fluidic Power Supply for the XM445 Fuze in Supersonic Wind Tunnels
【24h】

Performance of the Fluidic Power Supply for the XM445 Fuze in Supersonic Wind Tunnels

机译:超音速风洞中Xm445引信的流体动力源性能

获取原文

摘要

As part of the development of the fluidic power supply of the XM445 fuze, wind tunnel tests of different configurations of the power supply were conducted at the Naval Surface Weapons Center in November 1979. Power supply performance and pressure and temperature measurements within the fuze were recorded at Mach 1.5 and Mach 5 for a range of pressures. Success or failure of any given configuration was based on degree of sensitivity at low pressure and ability to operate at high pressure and temperature. Measurements of temperature and pressure provided new information on conditions in the fuze. (Author)

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号