首页> 美国政府科技报告 >Gaze Control during Horizontal and Vertical Target Tracking
【24h】

Gaze Control during Horizontal and Vertical Target Tracking

机译:水平和垂直目标跟踪中的注视控制

获取原文

摘要

The Honeywell oculometer has a noise level of about 0.1 deg(2): eye tracking is noisier than head tracking; vertical eye tracking is noisier than horizontal eye tracking. It has about 25% crosstalk of the horizontal channel into the vertical channel. It has an 84 ms time delay. It is not effective at detecting and rejecting eye blinks; typical eye blink artifacts last 50 to 200 ms. The human tracks best when tracking with eyes alone. Although tracking with head and eyes should be more natural, the human does worse when he uses his head. Head only tracking is the worst of the three conditions.