首页> 美国政府科技报告 >Evaluation of X-ray Fluorescence Unit for Detecting Lead in Paint on MilitaryStructures
【24h】

Evaluation of X-ray Fluorescence Unit for Detecting Lead in Paint on MilitaryStructures

机译:用于检测军事结构涂料中铅含量的X射线荧光单元的评价

获取原文

摘要

Despite the toxicity of lead as a pigment in paint, lead-base paint continued tobe used in the United States until the mid-1950's. It is more difficult to date the discontinued use of lead-base paints on Army structures in foreign countries because locally procured paints are allowed to contain higher amounts of lead than those purchased in the United States. This situation is causing concern for installation Directorates of Engineering and Housing (DEHs) in Germany. The objective of this work was to evaluate the x-ray fluorescence (XRF) lead detector to determine its suitability for field use for measuring the lead content of paint on military structures in West Germany. A Princeton Gamma Tech (PGT) XK-3 unit was purchased for evaluation. Field work showed the detector to be durable and reliable. Standardization readings can compensate for the effect of the substrate on the readings. Accurate results can be obtained using a limited number of readings and the unit can detect lead-base paint hidden by layers of nonlead paint.