首页> 美国政府科技报告 >Conformal Transducers and Kistler 6203 Transducers for Measuring Chamber Gas Pressure in Small Arms Ammunition.
【24h】

Conformal Transducers and Kistler 6203 Transducers for Measuring Chamber Gas Pressure in Small Arms Ammunition.

机译:共形传感器和Kistler 6203传感器用于测量小武器弹药中的气体压力。

获取原文

摘要

Today, copper crusher gauges have largely given way to quartz piezoelectric transducers for the measurement of pressure in small calibre gun firings. Recent developments in piezoelectric transducers have resulted in the creation of the conformal gauge. This device, fitted semi-permanently in the proof barrel, measures gas chamber pressure by directly sensing the resultant forces on the cartridge case. This report gives results of comparisons made between PCB type 117B conformal transducers and NATO approved Kistler 6203 transducers for the measurement of pressure of 7.62 mm and 5.56 mm calibre NATO ammunition in proof barrels.... Piezoelectric transducers, Gas pressure measurement, Cartridges, Calibration.

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号