首页> 美国政府科技报告 >Final Bioventing Pilot Test Work Plan for Base Exchange Service Station Underground Storage Tank Area, Vandenberg Air Force Base, California. Part I
【24h】

Final Bioventing Pilot Test Work Plan for Base Exchange Service Station Underground Storage Tank Area, Vandenberg Air Force Base, California. Part I

机译:加利福尼亚州范登堡空军基地基地交换服务站地下储罐区最终生物通风试验工作计划。第一部分

获取原文

摘要

This pilot test work plan presents the scope of an in situ enhanced biological degradation, or 'bioventing', pilot test for treatment of gasoline- contaminated soils at the Base Exchange Service Station (BXSS), Underground Storage Tank (UST) Area, Vandenberg Air Force Base (AFB), California. The pilot test has three primary objectives: (1) to assess the potential for supplying oxygen throughout the contaminated soil interval, (2) to determine the rate at which indigenous microorganisms will degrade fuel when stimulated by oxygen-rich soil gas, and (3) to evaluate the potential for sustaining these rates of biodegradation until fuel contamination is remediated to below the regulatory standards.