Microdialysis monitoring of cerebral metabolism is now performed in several neuro-intensive care units. Conventional microdialysis utilizes CMA70 catheters with 20 kDa molecular weight cut-off membranes enabling the measurement of small molecules such as glucose, lactate, pyruvate and glutamate. The CMA71 100 kDa molecular weight cut-off microdialysis catheter has recently been introduced to allow detection of larger molecules such as cytokines. The objective of this study was to perform in vitro and in vivo testing of the CMA71 microdialysis catheter, comparing its performance with the CMA70. In vitro comparison studies of three of each catheter using reference analyte solutions, demonstrated equivalent recovery for glucose, lactate, pyruvate and glutamate (range 94-97% for CMA70 and 88-103% for CMA71). In vivo comparison involved intracranial placement of paired CMA70 and CMA71 catheters (through the same cranial access device) in six patients with severe traumatic brain injury. Both catheters were perfused with CNS Perfusion Fluid without dextran at 0.3 mu l min(-1) with hourly sampling and bedside analysis on a CMA600 microdialysis analyser. The two catheters yielded equivalent results for glucose, lactate, pyruvate, glutamate and lactate/pyruvate ratio. CMA71 microdialysis catheters can, therefore, be used for routine clinical monitoring of extracellular substances, as well as for their intended research role of larger molecular weight protein sampling.
机译:现在在几个神经重症监护病房进行脑代谢的微透析监测。常规微透析利用具有20 kDa分子量截留膜的CMA70导管来测量小分子,例如葡萄糖,乳酸,丙酮酸和谷氨酸。最近引入了CMA71 100 kDa分子量截止微透析导管,可检测更大的分子,例如细胞因子。这项研究的目的是对CMA71微透析导管进行体外和体内测试,并将其性能与CMA70进行比较。使用参考分析物溶液对每个导管中的三个进行的体外比较研究表明,葡萄糖,乳酸,丙酮酸和谷氨酸的回收率相当(CMA70范围为94-97%,CMA71范围为88-103%)。体内比较涉及六名严重颅脑外伤患者的颅内放置成对的CMA70和CMA71导管(通过同一颅骨进入装置)。两个导管均以0.3μlmin(-1)灌注不含右旋糖酐的CNS灌注液,每小时取样并在CMA600微透析分析仪上进行床旁分析。这两个导管在葡萄糖,乳酸,丙酮酸,谷氨酸和乳酸/丙酮酸的比率上产生了相同的结果。因此,CMA71微透析导管可用于细胞外物质的常规临床监测,以及用于较大分子量蛋白质采样的预期研究作用。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号