首页> 外文期刊>Solvent Extraction and Ion Exchange >Laboratory-Scale Column Testing Using Crystalline Silicotitanate (IONSIV~(TM)IE-911)for Removing Cesium from Acidic Tank Waste Simulant.1:Cesium Exchange Capacity of a 15-cm~3Column and Dynamic Stability of the Exchange Media
【24h】

Laboratory-Scale Column Testing Using Crystalline Silicotitanate (IONSIV~(TM)IE-911)for Removing Cesium from Acidic Tank Waste Simulant.1:Cesium Exchange Capacity of a 15-cm~3Column and Dynamic Stability of the Exchange Media

机译:使用结晶硅钛酸盐(IONSIV〜(TM)IE-911)从酸性罐体废液模拟物中去除铯的实验室规模的柱测试.1:15 cm〜3柱的铯交换容量和交换介质的动态稳定性

获取原文
获取原文并翻译 | 示例
           

摘要

Bench-scale column tests were performed using a commercial form of crystalline silicotitanate(CST)for removing radio-cesium from a surrogate acidic tank solution representative of liquid waste stored at the Idaho National Engineering and Environmental Laboratory(INEEL).An engineered form of CST ion exchanger,known as IONSIV~(TM)IE-911(UOP,Mt.Laurel,NJ,USA),was tested in 15cm~3 columns at a flow rate of 5 bed volumes per hour.These experiments showed the ion exchange material to have reasonable selectivity and capacity for removing cesium from the complex chemical matrix of the solution.However,previous testing indicated that partial neutralization of the feed stream was necessary to increase the stability of the ion exchange media.Thus,in these studies,CST degradation was determined as a function of throughput in order to better assess the stability characteristics of the exchanger for potential future waste treatment applications.Results of these tests indicate that the degradation of the CST reaches a maximum very soon after the acidic feed is introduced to the column and then rapidly declines.Total dissolution of bed material did not exceed 3% under the experimental regime used.
机译:实验室规模的柱测试使用商业化形式的结晶硅钛酸盐(CST)进行,用于从替代酸性池溶液中去除放射性铯,该溶液代表爱达荷州国家工程和环境实验室(INEEL)所存储的液体废物。在15cm〜3的色谱柱中以每小时5个床体积的流速对称为IONSIV〜(TM)IE-911(UOP,Laurel,NJ,美国)的离子交换剂进行了测试。这些实验表明离子交换材料具有从溶液的复杂化学基质中除去铯的合理的选择性和能力。但是,先前的测试表明,进料流的部分中和对于提高离子交换介质的稳定性是必要的。因此,在这些研究中,CST降解为了更好地评估交换器的稳定性,以供将来潜在的废物处理应用之用,确定了其与通量的关系。这些测试的结果表明,在将酸性进料引入色谱柱后,CST很快达到最大值,然后迅速下降。在使用的实验方案下,床层物料的总溶解度不超过3%。

著录项

相似文献

  • 外文文献
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号