首页> 外文期刊>Photomedicine and laser surgery >Microleakage of class V cavities with different adhesive systems prepared by a diamond instrument and different parameters of Er:YAG laser irradiation.
【24h】

Microleakage of class V cavities with different adhesive systems prepared by a diamond instrument and different parameters of Er:YAG laser irradiation.

机译:用金刚石仪器和不同的Er:YAG激光辐照参数制备的具有不同粘合系统的V类空腔的微渗漏。

获取原文
获取原文并翻译 | 示例
           

摘要

OBJECTIVE: The aim of this study was to evaluate the microleakage of composite resin restorations using two different dentine adhesive systems prepared with a diamond instrument and different parameters of Er:YAG laser irradiation. BACKGROUND DATA: Information on this topic with regard to preparing class V cavities with different parameters of Er:YAG laser irradiation and adhesive systems is scarce. MATERIALS AND METHODS: Two hundred class V cavities were assigned to ten groups (n = 20 each): group 1: Er:YAG laser (5 Hz, 600 mJ) + phosphoric acid (PA) + Adper Single Bond 2 (ASB2); group 2: Er:YAG laser (10 Hz, 300 mJ) + PA + ASB2; group 3: Er:YAG laser (15 Hz, 200 mJ) + PA + ASB2; group 4: Er:YAG laser (20 Hz, 150 mJ) + PA + ASB2; group 5: diamond instrument + PA + ASB2; group 6: Er:YAG laser (5 Hz, 600 mJ) + Adper Prompt L-Pop (APLP); group 7: Er:YAG laser (10 Hz, 300 mJ) + APLP; group 8: Er:YAG laser (15 Hz, 200 mJ) + APLP; group 9: Er:YAG laser (20 Hz, 150 mJ) + APLP; and group 10: diamond instrument + APLP. Cavities were restored with a nanofill composite (Filtek Supreme XT Body). After thermocycling, the specimens were stained with 0.5% aqueous basic fuchsin dye and sectioned bucco-lingually. Dye penetration was then scored. The data were analyzed using the Kruskal-Wallis and Mann-Whitney U tests with Bonferroni correction. The Wilcoxon signed ranks test was used to compare occlusal and gingival scores. RESULTS: Leakage was seen in all groups at both the occlusal and gingival margins. The Kruskal-Wallis test showed statistically significant differences among the 10 groups (p < 0.001). The gingival margins had more microleakage than the occlusal margins (p < 0.001). Pairwise analysis by the Mann-Whitney U test showed that statistically significant differences (p < 0.05) in microleakage were found between groups 3 and 5 (3 > 5), 5 and 7 (7 > 5), and 7 and 8 (7 > 8) at the gingival margin, and between groups 3 and 6 (6 > 3), 3 and 7 (7 > 3), 4 and 6 (6 > 4), and 4 and 7 (7 > 4) at the occlusal margin. CONCLUSION: We concluded that for all groups, microleakage values were higher at the gingival margins. The use of the Er:YAG laser for cavity preparation with different parameters and different dentine adhesive systems influenced the marginal sealing of composite resin restorations.
机译:目的:本研究的目的是使用金刚石仪器制备的两种不同的牙本质粘合体系和不同参数的Er:YAG激光辐照,评估复合树脂修复体的微渗漏。背景数据:关于准备具有不同参数的Er:YAG激光辐照和粘合系统的V级腔的信息很少。材料与方法:将200个V类腔分为10组(每组n = 20):第1组:Er:YAG激光(5 Hz,600 mJ)+磷酸(PA)+ Adper Single Bond 2(ASB2);第2组:Er:YAG激光(10 Hz,300 mJ)+ PA + ASB2;第3组:Er:YAG激光(15 Hz,200 mJ)+ PA + ASB2;第4组:Er:YAG激光(20 Hz,150 mJ)+ PA + ASB2;第5组:钻石乐器+ PA + ASB2;第6组:Er:YAG激光(5 Hz,600 mJ)+ Adper Prompt L-Pop(APLP);第7组:Er:YAG激光(10 Hz,300 mJ)+ APLP;第8组:Er:YAG激光(15 Hz,200 mJ)+ APLP;第9组:Er:YAG激光(20 Hz,150 mJ)+ APLP;第10组:钻石仪+ APLP。用纳米填充复合材料(Filtek Supreme XT阀体)修复型腔。热循环后,将标本用0.5%碱性品红染料水溶液染色,并按颊舌切面。然后对染料渗透率进行评分。使用具有Bonferroni校正的Kruskal-Wallis和Mann-Whitney U检验分析数据。使用Wilcoxon符号秩检验来比较牙合和牙龈评分。结果:所有组在咬合和牙龈边缘均发现渗漏。 Kruskal-Wallis检验显示10组之间具有统计学显着性差异(p <0.001)。牙龈缘比牙合缘有更多的微渗漏(p <0.001)。通过Mann-Whitney U检验进行的成对分析显示,第3组和第5组(3> 5),第5和第7组(7> 5)以及第7和8组(7> 8)在牙龈边缘,以及第3和6组(6> 3),3和7(7> 3),4和6(6> 4),以及4和7(7> 4)组之间。结论:我们得出结论,对于所有组,牙龈边缘的微渗漏值均较高。 Er:YAG激光用于制备具有不同参数和不同牙本质粘合体系的腔体的方法影响了复合树脂修复体的边缘密封。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号