OBJECTIVE: To evaluate the temperature changes on the root's external surface during Er:YAG laser irradiation with different tips and pulse repetition rates. BACKGROUND DATA: There have been limited reports that correlate temperature variations with Er:YAG laser irradiation using different tips and pulse repetition rates. MATERIALS AND METHODS: Sixty roots of central incisors were sectioned 10 mm from the apex, biomechanically prepared, embedded in acrylic resin, and randomly distributed into six groups: the teeth in group I, group II, and group III were irradiated with an Opus 20 laser with a sapphire tip at 8, 10, and 15 Hz, respectively; the teeth in group IV, group V, and group VI were irradiated with the fiberoptic tip of a Kavo Key laser at 6, 10, and 15 Hz, respectively. Laser irradiation was applied for 20 sec to all teeth and temperature changes were recorded with thermocouples in the root surfaces. RESULTS: There were significant differences (p < 0.05) among pulse repetition rates: 6 and 8 Hz(2.36 degrees +/- 0.91 degrees C), 10 Hz (4.92 degrees +/- 1.60 degrees C), and 15 Hz (8.23 degrees +/- 2.78 degrees C); and radicular thirds: apical (8.33 degrees +/- 2.69 degrees C), middle (4.70 degrees +/- 1.60 degrees C), and cervical (2.48 degrees +/- 0.83 degrees C). No significant differences were seen between the two types of laser tips used (p > 0.05). CONCLUSION: The temperature changes on root external surfaces remained above the critical threshold (13 degrees C) during Er:YAG laser irradiation, except for irradiation with 15 Hz in the apical third. However, the type of Er:YAG laser tip used (sapphire or fiberoptic) did not affect the temperature variation.
机译:目的:评估在Er:YAG激光照射过程中,不同尖端和脉冲重复频率下根部外表面的温度变化。背景数据:很少有报道将温度变化与使用不同尖端和脉冲重复频率的Er:YAG激光辐照相关。材料与方法:将中切牙的根部切离根尖10毫米,生物力学制备,包埋在丙烯酸树脂中,随机分为6组:第一组,第二组和第三组的牙齿用Opus 20辐照蓝宝石尖端分别为8、10和15 Hz的激光;用Kavo Key激光的光纤尖端分别以6、10和15 Hz辐照IV组,V组和VI组的牙齿。对所有牙齿施加激光照射20秒,并用热电偶在牙根表面记录温度变化。结果:脉冲重复频率之间存在显着差异(p <0.05):6和8 Hz(2.36度+/- 0.91摄氏度),10 Hz(4.92度+/- 1.60摄氏度)和15 Hz(8.23度) +/- 2.78摄氏度);放射状的三分之二:顶端(8.33度+/- 2.69摄氏度),中部(4.70度+/- 1.60摄氏度)和宫颈(2.48度+/- 0.83摄氏度)。在使用的两种类型的激光头之间未发现显着差异(p> 0.05)。结论:在Er:YAG激光照射过程中,根尖外表面的温度变化保持在临界阈值(13摄氏度)以上,除了在心尖三分之一处以15 Hz辐射。但是,所使用的Er:YAG激光头的类型(蓝宝石或光纤)不会影响温度变化。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号