摘要

This study reports on efforts to increase the dose sensitivity of polymer gel dosimeters used in 3D radiation dosimetry. The potential of several different cosolvents is investigated, with the aim of increasing the solubility of N,N'-methylene-bisacrylamide crosslinker in polymer gel dosimeters. Glycerol and isopropanol increase the limit for the crosslinker solubility from approximately 3% to 5% and 10% by weight, respectively. This enables the manufacture of polymer gel dosimeters with much higher levels of crosslinking than was previously possible. New dosimeter recipes containing up to 5 wt% N,N'-methylene-bisacrylamide were subjected to spatially uniform radiation and were studied using nuclear magnetic resonance (NMR), as well as x-ray and optical CT techniques. The resulting dosimeters exhibit dose sensitivities that are up to 2.7 times higher than measured for a typical dosimeters with 3% N,N'-methylene-bisacrylamide without the addition of cosolvent. Two additional cosolvents (n-propanol and sec-butanol) were deemed unsuitable for practical dosimeters due to incompatibility with gelatin, cloudiness prior to irradiation, and immiscibility with water when large quantities of cosolvent were used. The dosimeters with high N,N'-methylene-bisacrylamide content that used isopropanol or glycerol as cosolvents had high optical clarity prior to irradiation, but did not produce suitable optical CT results for non-uniformly irradiated gels due to polymer development outside of the high dose regions of the pencil beams and significant light scatter. Further experiments are required to determine whether cosolvents can be used to manufacture gels with sufficiently high dose sensitivity for readout using x-ray computed tomography.
机译:这项研究报告了为提高3D辐射剂量法中使用的聚合物凝胶剂量计的剂量敏感性所做的努力。为了提高N,N'-亚甲基-双丙烯酰胺交联剂在聚合物凝胶剂量计中的溶解度,研究了几种不同助溶剂的潜力。甘油和异丙醇将交联剂溶解度的极限分别从约3%增加至5%和10%重量。这使得能够制造具有比以前可能更高的交联水平的聚合物凝胶剂量计。含有不超过5 wt%N,N'-亚甲基双丙烯酰胺的新剂量计配方在空间上受到均匀辐射,并使用核磁共振(NMR)以及X射线和光学CT技术进行了研究。所得的剂量计显示出的剂量敏感性比不添加助溶剂的3%N,N'-亚甲基双丙烯酰胺的典型剂量计高2.7倍。两种其他助溶剂(正丙醇和仲丁醇)被认为不适合实际剂量计,因为它们与明胶不相容,辐射前混浊,以及在使用大量助溶剂时与水不混溶。使用异丙醇或甘油作为助溶剂的具有高N,N'-亚甲基双丙烯酰胺含量的剂量计在辐照前具有较高的光学透明度,但由于聚合物在高能级之外发展,因此无法对非均匀辐照的凝胶产生合适的光学CT结果。笔形光束的剂量区域和明显的光散射。需要进一步的实验来确定是否可以使用助溶剂来制备具有足够高剂量敏感性的凝胶,以使用X射线计算机断层扫描进行读出。

著录项

相似文献

  • 外文文献
  • 中文文献
  • 专利
获取原文

客服邮箱:kefu@zhangqiaokeyan.com

京公网安备:11010802029741号 ICP备案号:京ICP备15016152号-6 六维联合信息科技 (北京) 有限公司©版权所有
  • 客服微信

  • 服务号